Език: EN EN
← Назад към резултатите
Набира участници Не е приложимо NCT07089576

Clinical Study to Evaluate the Safety and Effectiveness of Arcevo LSA

Не е приложима фаза (напр. обсервационно)
Заболявания: Aortic Arch Aneurysm Aortic Arch Dissection Chronic Aortic Dissection Acute Aortic Dissection

Спонсор: Artivion Inc.

Налично на: БГ
Обобщение
The goal of this clinical trial is to learn if the Arcevo LSA stent graft can safely and effectively treat patients that have an acute or chronic aortic dissection and/or aneurysm that involves the aortic arch and the descending thoracic aorta, with or without the involvement of the ascending aorta.
Кой може да участва
General Inclusion Criteria 1. ≥18 years of age or ≤80 years of age (male or female) at time of surgery 2. Patient has one of the following indications for open surgery based on computed tomography angiography (CTA) completed within 90 days of informed consent: * Acute, subacute, or chronic dissection that involves the aortic arch and the descending thoracic aorta, with or without involvement of the ascending aorta * Aneurysm that involves the aortic arch and the descending thoracic aorta, with or without involvement of the ascending aorta 3. Patient, or patient's legally authorized representative (LAR; in the secondary arm only), provides written informed consent prior to any study procedures 4. Patient's surgery occurs within 90 days of informed consent Anatomical Inclusion Criteria 5. Aortic diameter at the intended Arcevo™ LSA anastomosis site is ≥ 21 mm 6. For Aneurysm with distal sealing (i.e., single stage procedure), aortic diameter at the intended distal sealing zone is between 20-36 mm 7. For Dissection with distal sealing, aortic diameter at the intended distal sealing zone is between 22-40 mm 8. LSA branch does not require additional stenting further into the LSA (beyond the Arcevo™ LSA) 9. The intended LSA sealing zone has a diameter between 8.5 mm and 14.0 mm with a length of at least 10 mm 10. Absence of dissection, aneurysm, or stenosis in the intended LSA sealing zone 11. The intended LSA branch position does not interrupt flow to any branch vessel (e.g., left vertebral artery) 12. Patient does not have computed tomography (CT) evidence of extreme arch or LSA angulation precluding safe passage of the Arcevo™ LSA and delivery system 13. LSA take-off angle between 15° and 90° 14. For patients requiring planned extension, there is a ≥ 2 cm distal seal zone for the TEVAR device without a severely angulated descending aorta 15. For patients requiring planned extension, patient has suitable iliac artery anatomy for safe passage of the TEVAR delivery system General Exclusion Criteria 1. Patient is pregnant, or planning to become pregnant during the course of the study; individuals of child-bearing potential must agree to use acceptable methods of contraception during the study 2. Patient has another medical condition (aside from the arch disease) that, in the opinion of the investigator, reduces the patient's life expectancy to \< 2 years 3. Patient has an existing aortic stent graft device in the descending aorta that would interact with Arcevo™ LSA 4. Patient has a medical, social, or psychological problem that, in the opinion of the investigator, could impede the patient's ability to return for follow-up 5. Patient is unwilling or unable to comply with the follow-up schedule 6. Patient is institutionalized due to administrative or judicial order 7. Patient is unwilling to accept blood transfusion or blood product 8. Patient is currently participating in another interventional clinical study which includes treatment with another investigational product (e.g., device, pharmaceutical or biologic) Medical Exclusion Criteria 9. Patient is unfit for open surgical repair involving circulatory arrest 10. Patient is in extreme hemodynamic compromise requiring cardiopulmonary resuscitation (CPR) or substantial inotropic support prior to surgery 11. Patient has an active systemic infection 12. Patient has endocarditis or active infection of the aorta 13. Patient has a freely ruptured aorta 14. Patient has a history of a bleeding disorder (e.g., hemophilia) 15. Patient has current end-stage renal disease (e.g., GFR \<30 mL/min) 16. Patient has a known allergy to Arcevo™ LSA components and TEVAR device components (if required) (nitinol, polyester, platinum-iridium, or polyethylene) 17. Patient has uncontrollable anaphylaxis to iodinated contrast or other inability to obtain CT angiograms during follow-up 18. Patient has acute coronary malperfusion 19. Patient has symptomatic visceral malperfusion
Интервенции
Arcevo™ LSA Hybrid Stent Graft System
DEVICE
Места на провеждане 16
САЩ (16)
University of Michigan
Ann Arbor , Michigan
Emory University School of Medicine
Atlanta , Georgia
University of Colorado Hospital
Aurora , Colorado
University of Texas - Austin
Austin , Texas
Johns Hopkins Hospital
Baltimore , Maryland
Northwestern University Feinberg School of Medicine
Chicago , Illinois
Cleveland Clinic Foundation
Cleveland , Ohio
University of Texas, McGovern Medical Center
Houston , Texas
University of Southern California
Los Angeles , California
Medical College of Wisconsin
Milwaukee , Wisconsin
Columbia University Irving Medical Center/New York Presbyterian Hospital
New York , New York
Cornell Medical College (Presbyterian Weill)
New York , New York
Northwell Health
New York , New York
Allegheny General Hospital
Pittsburgh , Pennsylvania
Baylor Scott & White
Plano , Texas
Montefiore Medical Center
The Bronx , New York
Технически детайли
Статус
Набира участници
Фаза
Не е приложимо
Вид изследване
INTERVENTIONAL
Пол
Мъже и жени
Минимална възраст
18 Years
Максимална възраст
80 Years
Здрави доброволци
Не
Начална дата
04.11.2025
Крайна дата
01.07.2032
Регистрационен номер
NCT07089576
Източник
clinicaltrials.gov
Запитване за медицински туризъм

Информацията е извлечена автоматично от ClinicalTrials.gov. Консултирайте се с вашия лекар преди да предприемете действия.